• CP104

    CP104

    CP104 is designed with 3 mounting holes. It is for long-term monitoring or development testing. CP104 pressure transducer may be operated with either softline or hardline cables depending on the required temperature. It can be mounted on various parts of the machine where enclosed pressure can be measured (hydraulic block, combustion chamber, etc.).

    Read more
  • EA401

    EA401

    • Very high-quality, reliable extension cable for TQ401 proximity measurement systems
    • 50 Ω coaxial cable with FEP insulation (Ø 2.65 or 3.6 mm)
    • 1-core, with shield
    • Self-locking miniature coaxial connector (female) to self-locking miniature coaxial connector (male)
    • Certified for use in potentially explosive atmospheres
    Read more
  • EA402

    EA402

    The system is based around a TQ403 non-contact sensor and an IQS900 signal conditioner. Together, these form a calibrated proximity measurement system in which each component is interchangeable. The system outputs a voltage or a current proportional to the distance between the transducer tip and the target, such as a machine shaft.

    The active part of the transducer is a coil of wire that is moulded inside the tip of the device, made of (polyamide-imide). The transducer body is made of stainless steel. The target material must, in all cases, be metallic.

    The transducer body is available only with metric thread. The TQ403 has an integral coaxial cable, terminated with a self-locking miniature coaxial connector. Various cable lengths (integral and extension) can be ordered.

    Read more
  • EA902

    EA902

    • Very high-quality, reliable extension cable for TQ9x2 proximity measurement chains
    • 70 Ω coaxial cable with FEP insulation (Ø3.6 mm)
    • 1-core, with shield
    • Self-locking miniature coaxial connector (female) to self-locking miniature coaxial connector (male)
    • Versions certified for use in potentially explosive atmospheres
    • Conforms to API 670 5th edition
    Read more
  • IC693

    IC693

    Series 90-30 (IC693) GE Fanuc PLC

    Read more
  • IC695

    IC695

    GE IC695/IC693/IC697/IC698 Series – PLC DCS

    Read more
  • IC697

    IC697

    GE IC695/IC693/IC697/IC698 Series

    Read more
  • IOC4T

    IOC4T

    • From  • Signal interface card with 4 dynamic signal inputs and 2 tachometer (speed) inputs, for the MPC4 machinery protection card
    • Screw-terminal connectors (48 terminals) for all input/output connections
    • Contains 4 relays which can be attributed to alarm signals, under software control
    • 32 fully-programmable open-collector outputs (jumper selectable) to IRC4 and RLC16 relay cards
    • Buffered “raw” sensor signals and analog output signals (voltage or current) for vibration channels
    • EMI protection for all inputs and outputs • Live insertion and removal of cards (hot-swappable)
    • Available in “standard” and “separate circuits” versions

    Read more
  • IQS450

    IQS450

    he system is based around a TQ423 non-contact sensor and an IQS450 signal conditioner. Together, these form a calibrated proximity measurement system in which each component is interchangeable. The system outputs a voltage or a current proportional to the distance between the transducer tip and the target, such as a machine shaft.

    The TQ423 is specially designed for high-pressure applications, with the transducer tip withstanding pressures of up to 100 bar. This makes them particularly suitable for measuring relative displacement or vibration on submerged pumps and various types of hydraulic turbines (for example, Kaplan and Francis). This transducer is also suitable for use when the region of the output of the transducer is cluttered.

    Read more
  • IQS450

    IQS450

    The system is based around a TQ423 non-contact sensor and an IQS450 signal conditioner. Together, these form a calibrated proximity measurement system in which each component is interchangeable. The system outputs a voltage or a current proportional to the distance between the transducer tip and the target, such as a machine shaft.

    The TQ423 is specially designed for high-pressure applications, with the transducer tip withstanding pressures of up to 100 bar. This makes them particularly suitable for measuring relative displacement or vibration on submerged pumps and various types of hydraulic turbines (for example, Kaplan and Francis). This transducer is also suitable for use when the region of the output of the transducer is cluttered.

    Read more
  • IQS900

    IQS900

    • Signal conditioning for TQ proximity sensors.
    • Shaft relative vibration and gap/position measurement for machinery protection and/or advanced condition monitoring.
    • Very wide frequency range (DC to 20000 Hz), with configurable sensitivity and measurement range.
    • Current output for long-distance signal transmission or voltage output for medium-distance signal transmission.
    • Certified for use in potentially explosive atmospheres (Ex) and/or safety-related applications (SIL).
    • Fully compliant with API 670 5th edition.
    Read more
  • Logix5000 1756

    Logix5000 1756

    ControlLogix. Interface cable. Length 3m. 9 pin D-shell to 9 pin D-shell

    Read more